This test method is a widely used standard procedure for measuring the peroxide value, which quantifies the amount of peroxides and hydroperoxides—primary oxidation products—in oils and fats. Oil is extracted from the feed sample prior to a titration to determine the free fatty acid content. This value is an important indicator of the early stages of lipid oxidation and rancidity.