This test method is a validated gas chromatography (GC) method for determining cholesterol content in a wide range of foods, including meats, dairy products, and processed items. It involves extraction, saponification, and derivatization steps to isolate cholesterol from the sample matrix, followed by quantification using a GC with a flame ionization detector (FID).